• Home
  • Privacy policy
  • Italiano
  • English
  • Home
  • Privacy policy
  • Italiano
  • English
  • Software
    • ECT
      • ACKNOWLEDGEMENT
      • SYSTEM REQUIREMENTS
      • COMMUNICATION SCHEMES
      • DIRECTORY STRUCTURE
      • AVAILABLE TOOLS
      • INSTALLATION
      • GETTING STARTED
      • MAIN MENU
      • DEVICE EDITOR
        • ELF ORIENTED DEVICES AND NOT ELF ORIENTED DEVICES
        • STORAGE STRUCTURE OF THE DEVICE DATABASES
        • DEVICE LIST
          • CONTEXTUAL MENU IN THE DEVICE LIST
          • TOP BAR MENU
        • PAGE FOR EDITING THE VALUES IN THE DATABASE
          • TOP BAR MENU
          • MAIN - COMMUNICATION PARAMETERS AND OTHER SETTINGS
          • SCALINGS SECTION
          • INCREMENT SECTION
          • GROUPS SECTION
          • CHANNELS
          • CALIBRATION PARAMETERS
          • MEMORY MAP
        • COMMAND LINE USAGE
      • MEMORY INTERFACE
        • SEND (PC->ECU)
        • LEARN
        • RESET DIAGNOSTIC DATA
        • HDP/CRP MANAGER
        • MEMORYINTERFACE SETTINGS
      • DISPLAY
        • TYPES OF CONTAINERS
        • PROFILE STRUCTURE
        • CONTAINER MANAGEMENT
        • CONTROLS
        • MODIFICATION OF A CONTAINER
        • DATA RECORDING - F3 LOG
        • DISPLAY SETTINGS
      • CALIBRATION EDITOR
        • CALIBRATION TYPES
        • LOADING A CALIBRATION
        • WORKING WITH CALIBRATION EDITOR
        • CALIBRATION COMPARISON
        • PRINT THE VALUES OF THE CALIBRATION VARIABLES
        • SAVING CHANGES
        • DELETING A CALIBRATION FILE
        • CALIBRATION SETTINGS
      • ASAP3
      • CHARTING TOOL
        • LOADING A DATA FILE
        • MAIN MENU
        • CHANNEL LIST
        • CURSOR
        • SEGMENTS
        • DISPLAY LAYOUT
        • DISPLAY ORIENTATION
        • ZOOM
        • LINK ANALYSIS DISPLAY WITH ENGINE MAP
      • APPENDICES
        • STRING FORMAT
      • VERSION HISTORY

CALIBRATION SETTINGS

93 views 0

 

In this page you can configure the options to suit your needs:


 


Enable Learn calibration:
Enables the menu item that allows to load the frame for the learn calibration.

This option is meaningful only for systems that require a learn calibration and that contain a descriptor of this type in the device.

The management of a calibration of learn within the dedicated frame is entirely similar to the management of a main calibration, with the exception that the calibration of learn can not be managed online.

Enable Setup calibration:
Enables the menu item that allows to load the frame for the setup calibration.

This option is meaningful only for systems that require a setup calibration and contain a descriptor of this type in the device.

The management of a calibration setup within the dedicated frame is entirely similar to the management of a main calibration, with the exception that the calibration setup may provide an instruction to reset the control unit at the end of the editing work.

Show all break points:

If a curve or a map have breakpoints that are not equispaced, you can ‘delete’ breakpoints. The deletion is in fact a reassignment of the value of the breakpoint to be deleted. After the ‘deletion’, the value of the deleted breakpoint becomes equal to the value of the first breakpoint. In the presence of equal breakpoints in the first positions, the default behaviour of ECT is to disable the display of all the equal breakpoints except 1. Enabling this option you will always get to see all breakpoints even if there are breakpoints with equal values in the first positions.

The edit point automatically follows the edit point

If a curve or map is loaded from ECU it is possible to enable the animation of the breakpoints, i.e. it is possible to see which point of the curve or map is active according to the values of the breakpoints . The edit point, on the other hand, is independent and is the cell selected by the user.

By activating this option, the edit point is automatically moved to the animation point.

The user must confirm the off-line changes by pressing F8

If a curve or map is loaded, changes to the values of the curve or map are not immediately confirmed but the user must use the F8 command to confirm them.

By activating this option the changes are immediately confirmed.

The user must confirm the on-line changes by pressing F8

If a curve or map is loaded, changes to the curve or map values are not immediately confirmed and transmitted to the control unit but it is necessary for the user to use the F8 command to confirm and transmit the changes to the control unit.

By activating this option, the changes are immediately confirmed and transmitted to the control unit.

Also compare different types of calibrations

If this parameter is enabled, you can compare a main calibration with a setup calibration.

Show information about the selected variable in area below the list of variables

If this parameter is enabled, the application displays the notes about the variable and the groups the variable belongs to.

Enable the change of name and date when saving

The option, if enabled, allows to update the name and date field when saving. If this option is disabled, the save command does not involve any modification of the name and date field.

User is prompted to confirm the change of name and the date when saving

This option, when enabled, results in a request of confirmation of the change of the name and date field. If disabled and if the change of name and date field is enabled, the field will be changed without prompting the user.

Show curve values vertically

By default the values of a curve are listed horizontally in a row. This option allows to show the values in a column.

Map axes are swapped

By default, in a map, the column headers show the first axis values and the row headers show the second axis values. This option allows you to invert the 2 axes.

Was this helpful?

Yes  No
Related Articles
  • VERSION HISTORY
  • STRING FORMAT
  • APPENDICES
  • ASAP3
  • PRINT THE VALUES OF THE CALIBRATION VARIABLES
  • LINK ANALYSIS DISPLAY WITH ENGINE MAP