• Home
  • Privacy policy
  • Italiano
  • English
  • Home
  • Privacy policy
  • Italiano
  • English
  • Software
    • ECT
      • ACKNOWLEDGEMENT
      • SYSTEM REQUIREMENTS
      • COMMUNICATION SCHEMES
      • DIRECTORY STRUCTURE
      • AVAILABLE TOOLS
      • INSTALLATION
      • GETTING STARTED
      • MAIN MENU
      • DEVICE EDITOR
        • ELF ORIENTED DEVICES AND NOT ELF ORIENTED DEVICES
        • STORAGE STRUCTURE OF THE DEVICE DATABASES
        • DEVICE LIST
          • CONTEXTUAL MENU IN THE DEVICE LIST
          • TOP BAR MENU
        • PAGE FOR EDITING THE VALUES IN THE DATABASE
          • TOP BAR MENU
          • MAIN - COMMUNICATION PARAMETERS AND OTHER SETTINGS
          • SCALINGS SECTION
          • INCREMENT SECTION
          • GROUPS SECTION
          • CHANNELS
          • CALIBRATION PARAMETERS
          • MEMORY MAP
        • COMMAND LINE USAGE
      • MEMORY INTERFACE
        • SEND (PC->ECU)
        • LEARN
        • RESET DIAGNOSTIC DATA
        • HDP/CRP MANAGER
        • MEMORYINTERFACE SETTINGS
      • DISPLAY
        • TYPES OF CONTAINERS
        • PROFILE STRUCTURE
        • CONTAINER MANAGEMENT
        • CONTROLS
        • MODIFICATION OF A CONTAINER
        • DATA RECORDING - F3 LOG
        • DISPLAY SETTINGS
      • CALIBRATION EDITOR
        • CALIBRATION TYPES
        • LOADING A CALIBRATION
        • WORKING WITH CALIBRATION EDITOR
        • CALIBRATION COMPARISON
        • PRINT THE VALUES OF THE CALIBRATION VARIABLES
        • SAVING CHANGES
        • DELETING A CALIBRATION FILE
        • CALIBRATION SETTINGS
      • ASAP3
      • CHARTING TOOL
        • LOADING A DATA FILE
        • MAIN MENU
        • CHANNEL LIST
        • CURSOR
        • SEGMENTS
        • DISPLAY LAYOUT
        • DISPLAY ORIENTATION
        • ZOOM
        • LINK ANALYSIS DISPLAY WITH ENGINE MAP
      • APPENDICES
        • STRING FORMAT
      • VERSION HISTORY

MEMORYINTERFACE SETTINGS

52 views 0

In this page you can configure the ECT facilities available to suit your needs:

Enable learn tools:

Enables the corresponding menu item

Enable Setup Calibration:

Enables the menu items related to the management od the setup calibration.

Enable device based custom tools

Enables the menu item related to the management of the custom tools

 

MD5

the MD5 of the bytes of a calibration can be used to verify that a calibration in the control unit is the same as a that of a calibration previously downloaded to disk.

Calculate MD5 of the calibrations downloaded from the control unit and save the result on file

Enables saving the MD5 of the calibrations downloaded from the ECU to file.

Enable the calibration MD5 verification command

Enables a command that allows you to browse a file containing the MD5 of the bytes of a previously downloaded calibration and check the equality with the MD5 of the calibration bytes on the ECU.

 

Enable HDP-CRP management:

Enables the corresponding menu item

Show the device name for binary files for binary files included in HDP and CRP files

Store the device name for binary files included in CRP files

 

Enable flashing of files in HDR CPT HDP CRP format:

Enable the ability to flash files with these extensions. These are preset files that contain all the information to program the control unit even if the device with which they were generated is missing.

 

Ignore possible presence of crypting dongle:

In the case where it is necessary to program certain types of software in an encrypted form, it is necessary to ask EFI to program the encryption keys within the sw of the communication interface. During the programming of the sw, ECT will read the encryption keys from the interface and will thus be able to encrypt the sw before sending it to the ECU. However, it may occur that the same user has to program with the same interface other types of sw which must not be encrypted. In this case the user can inhibit the use by ECT of the keys stored in the interface by checking this option.

 

Enable reading of memory areas:

Enables the corresponding menu item

Enable diagnostic data reset:

Enables the corresponding menu item

Enable output diagnosis:

Enables the corresponding menu item

Enable counter reset:

Enables the corresponding menu item

 

Continuous check of consistency between selected device and ECU Firmware

The ELF-oriented device, when they are connected to the PC through the USB interface, are able to transmit a string identifying the version of firmware. Consequently, ECT is able to check whether the string received from the controller is equal to the contents of the corresponding variable stored in the XML database of the device and derived from the ELF file used to define the database. In the event that the 2 variables, the one received from the controller and the one stored in the database, do not match, ECT notifies the inconsistency blocking communication and yellow colouring the background of the text box that indicates the communication id of the selected device. The option in question can disable this check, which would involve a demand on the CAN line approximately every 2.5 sec.

Continuous check of the encryption status

Enables real-time verification of the presence of encryption keys in the communication interface. The presence of the keys is shown on the screen in an icon in the command bar.

 

Detect and use removable drives

Enable detection and use of removable drives. If active, it allows you to select the files to be flashed also on removable drives.

Use network drives

Enable the use of network drives. If active, it allows you to select the files to be flashed also on network drives.

 

Name and date calibration element management:

The main calibration and the setup calibration contain a field that stores the name and date of calibration. The following options allow you to manage the synchronization strategy between name and date of the file and the content of the field ‘name and date’ of the calibration.

Enable the change of name and date when saving

If this option is enabled, after downloading a calibration, ECT asks if it has to update the name and date of calibration stored in the calibration using the file name and the current date of the PC. If this option is disabled, the field of the calibration will remain unchanged.

User is prompted to confirm the change of name and date when saving

This option can enable/disable the request to confirm the change of the name and date field. If this option is disabled and the previois option is enabled, ECT will automatically modify the the name and date field.

Was this helpful?

Yes  No
Related Articles
  • VERSION HISTORY
  • STRING FORMAT
  • APPENDICES
  • ASAP3
  • PRINT THE VALUES OF THE CALIBRATION VARIABLES
  • LINK ANALYSIS DISPLAY WITH ENGINE MAP

Didn't find your answer? Contact Us

Previously
HDP/CRP MANAGER
Up Next
DISPLAY
Copyright 2026 EFI Technology S.r.l. (Company subject to the management and coordination activities of MTA S.p.A.) All Rights Reserved.
We use cookies to make sure you can have the best experience on our site. If you continue to use this site we will assume that you approve our use of cookies.